乐发II500Name: Chongqing Fang Tai new building materials Co., Ltd.
Cell phone: 18680891886
乐发II500Phone: 023-88365054
乐发II500Fax: 023-88929344
Official website: bypiju.com
Address: Chongqing Jiulongpo Branch City Road No. 68, No. 9-1
The public toilet barrier free facilities and design requirements shall be in accordance with the provisions of the following table
Design requirements for facility category
乐发II500The ground slope outside the entrance entrance should not be more than 1:50
The door fan should comply with 19 relevant regulations
The ground should be skid and non water, and the width should not be less than 1.50M
乐发II500A safe grasp rod should be set at the 50mm side of the hand washbasin at the two sides of the hand wash basin, and the area should be used for the use of the 1.1mx0.8m wheelchair.
There should be a wide 0.6-0.7m and high 1.2m safety grip on both sides and above the urinals in the male toilet, and the lower mouth of the urinal should not be more than 0.50m
乐发II500Barrier free toilet male and female public toilet shall set up a barrier free toilet, toilet seat compartment area of not less than 1.8x1.4m, entrance width is more than 0.80M, the inside of the door leaf should be closed toilet handle, high 0.45M, high 0.70M level should be located on both sides, one side wall grab bar should be set high 1.40M vertical grab bar
乐发II500Safety grasp rod safety grasp rod diameter should be 30-40mm, distance from the wall 40mm, grasp the rod should be firmly installed
22. the barrier free facilities and design requirements should comply with the provisions of the following table
乐发II500Design requirements for facility category
To set up position government organs and major public buildings and main sections of the city, special toilet free toilets should be set up
The ground slope outside the entrance entrance should not be more than 1:50
The door fan should comply with 19 relevant regulations
Area greater than 2.00mX2.00m
A safe grasp rod should be set at the 50mm side of the hand washbasin at the two sides of the hand wash basin, and the area should be used for the use of the 1.1mx0.8m wheelchair.
乐发II500The height of the stool is 0.45M, and the two sides are set up with a high 0.70M horizontal grip and a high 1.40M vertical grip should be set on the side of the wall.
Hanger hook with high 1.20m
Call button is 0.40m - 0.50m at the height of the ground - call button
乐发II500Safety grasp rod safety grasp rod diameter should be 30-40mm, distance from the wall 40mm, grasp the rod should be firmly installed
23. public buildings with audience seats and audience seats should be set up in wheelchair seats
乐发II500Wheelchair seats should be located near the accessible and evacuating and passageway. Wheelchair seats should not be located in the public passageway. The occupation area of each wheelchair should not be less than 1.10mX0.80m.
The wheelchair seats on the ground should be flat, the installation of a handrail board should be at the edge; watch the show and match sight should not be occluded in the wheelchair seat, but also should not block the sight of others; the theater, auditorium, museum and other cultural audience seats below 1500 are advised to set up 2-4 wheelchairs, gymnasium and swimming hall the number of seats in the audience (field) below 6000 are advised to set up 4-6 wheelchairs, stadium seats below 60000 are advised to set up 6-10 wheelchairs, a small place and reading room seats for spectators at the age of 500 are advised to set up 1-2 wheelchair spaces.
乐发II50024. the public buildings with guest rooms should be equipped with barrier free rooms. Their facilities and design requirements should be in accordance with the provisions of the following table