Name: Chongqing Fang Tai new building materials Co., Ltd.
乐发II500Cell phone: 18680891886
乐发II500Phone: 023-88365054
Fax: 023-88929344
乐发II500Official website: bypiju.com
Address: Chongqing Jiulongpo Branch City Road No. 68, No. 9-1
The scope of the barrier free design for the viewing performance and the sports building should be in accordance with the following provisions
乐发II500Performance and sports buildings, must be in the following parts: the design of barrier free facilities construction base (pedestrian access, parking spaces), building entrance, entrance platform and doors, horizontal and vertical transportation, lobby lounge, auditorium, podium, VIP lounge, stage, backstage, rehearsal room, dressing room, training venues the venue, the audience, toilet, toilet and bathroom, actors, athletes ticket office, public telephone, drinking water and other relevant facilities. It includes theaters, theaters, cinemas, concert halls, auditorium, conference center, stadium, gymnasium, natatorium, skating hall, rink, gymnasium and so on.
乐发II50010. the scope of the barrier free design for traffic and medical buildings should be in accordance with the following provisions
乐发II500Transportation and medical construction, must be in the following parts: the design of barrier free facilities in the station square, pedestrian access, parking spaces, courtyard, building entrance door, horizontal and vertical transport, ticketing, inspection channel, terminal, car, ship and transit area, baggage, extraction, storage and commercial service area, the boarding bridge, the bridge tunnel, bridge, platform, to reach areas, outpatient room, emergency room, hospital wards, nursing room, Radiology, inspection and check, physiotherapy room, public toilet, service desk, registration, medicine, public telephones, drinking fountains and Taiwan etc.. It includes airport terminal, railway passenger station, bus passenger station, subway passenger station, port passenger station, general hospital, specialized hospital, sanatorium, rehabilitation center, emergency center, other medical and recuperative buildings.
11. the scope of the barrier free design for schools and gardens should be in accordance with the following provisions
乐发II500Garden buildings and schools, must be in the following parts: the design of barrier free facilities construction base (pedestrian access, parking spaces), building entrance, entrance platform and doors, horizontal and vertical transportation, ordinary classrooms, classrooms, laboratories, library, nature, history, art, calligraphy, music classroom, playground the exhibition area, swimming pool, and performing areas, children's activity area, indoor and outdoor public toilet, ticket office, service station, public telephones, drinking fountains and other relevant facilities. 包括高等院校、专业学校、职业高中与中、小学及托幼、培智学校、聋哑和盲人学校、城市广场、公园、街心花园、动物园、植物园、海洋馆、游乐园与旅游景点等建筑。
乐发II50012. barrier free design for high-rise, middle and high-rise residential buildings and apartment buildings
Building entrance, entrance platform, waiting hall, elevator car, public walkway, barrier free housing.
13. the barrier free design of the road in the residential area should include the following scope
The sidewalks of the residential road, the pedestrian walkway of the District Road, the sidewalks of the group road and the sidewalks on the road between the houses.
乐发II500The scope of barrier free design for public green space in 14. residential areas
乐发II500Residential park (residential area), small garden (district level), green groups (group level), children's playground.
15. when the entrance of high and middle high-rise buildings is set up, wheelchair ramp and barrier free handrails must be set.
16. the minimum width of the platform of the building entrance wheelchair
Large and medium-sized public buildings are larger than 2.00m, small public buildings are larger than 1.50M, high-rise buildings and apartment buildings are larger than 2.00m, many low level barrier free residences and apartment buildings are larger than 1.50M, and barrier free dormitory buildings are larger than 1.50M.
17. in the case of different slopes, the height and length of the ramp should be in accordance with the regulations in the following table