乐发II500

中文 | RSS | XML |
重庆无障碍扶手

categories of news

Product Categories

hot key words

contact us

Name: Chongqing Fang Tai new building materials Co., Ltd.

乐发II500Cell phone: 18680891886

乐发II500Phone: 023-88365054

乐发II500Fax: 023-88929344

Official website: bypiju.com

Address: Chongqing Jiulongpo Branch City Road No. 68, No. 9-1


Barrier free design should meet the requirements of the blind

Your current location: Home >> News >> Company news

Barrier free design should meet the requirements of the blind

Release date:2017-10-30 Author: Click:

乐发II500Specification for architectural barrier free design

Standard of barrier free design for urban roads and buildings

乐发II500In order to standardize the construction of barrier free facilities, the Ministry of Construction issued the "barrier free design code for urban roads and buildings", of which 24 are mandatory standards for engineering construction, which have been implemented since August 21, 2001.

乐发II500Requirements for the barrier free facilities and design requirements for 1. people on the road

Curb ramp sidewalk should be provided at intersection, neighborhood intersection, unit exit, Plaza entrance, crosswalk, bridge, tunnel and intersection. Curb ramp mouth high roadway ground shall not be greater than 2cm.

Ramp and stairway - the city's main roads, buildings and residential areas and pedestrian underpass, wheelchair ramps and stairways should set up safety; on both sides of the ramp and the ladder should be set no obstacle handrail. In the central area of the city, a vertical elevator can be set up to replace the wheelchair ramp.

Blind road, city center square, pedestrian street, commercial street, bridge, tunnel, intersections and the main building of the sidewalk area should be blind road; pedestrian underpass, pedestrian crossing and the main bus station should be prompted to blind.

Crosswalk - crosswalk safety island should enable wheelchairs to pass; pedestrian crosswalk on the main roads of the city should be equipped with street sound signals.

乐发II500Logo - in the city square, pedestrian street, commercial street, pedestrian bridge, pedestrian tunnel and other barrier free facilities, the international barrier free signs should be set up.

乐发II5002. the design of the slope of a single side slope should be in accordance with the following regulations

乐发II500Square, rectangular or fan-shaped, square, rectangular single side slope can be used as the width of the sidewalk. The width of the lower edge of the slop on the fan-shaped single side slope should not be less than 1.5M. At the corner of the road, the width of the upper edge of the single side slope of the slope should not be less than 2.00M. The slope of one side slope should not be more than 1:20.

乐发II5003. blind design shall comply with the following provisions

乐发II500Set the location and direction of the blind sidewalk, should be convenient for the visually disabled to walk and reach the barrier free facilities location.

Guide the disabled walk blind should be marching in the bar blind; the starting point and end point and moving the blind corner should be set dotshaped tips blind. Travel tips and blind blind width should be 0.3 - 0.6m.

The blind surface touch below thickness should be consistent with the sidewalk brick.  A blind touch width 0.25mm and height of 5mm.

乐发II500The blind should be continuous, midway may not have poles, wires, trees and other obstacles. Walking away from the obstacle should be 0.25 - 0.5m.

乐发II500Typhlosolis should avoid manhole laying; blind color should be yellow.

4. city main roads and residential areas of the bus station, and the blind Braille signs should be prompted. That blind length should be 4 - 6 meters.

乐发II500Triangular space area 5. pedestrian bridge under the installation of protective fence should be below 2M, and should be in the structure of the edge width 0.30m 0.60m peripheral blind road tips.

6. the scope of the barrier free design for office and scientific research buildings should be in accordance with the following provisions

乐发II500All levels of government office, the judiciary at all levels, enterprises and public office, all kinds of scientific and other business, office and community service construction, must be in the following parts: base design of barrier free facilities (pedestrian access, parking spaces), building entrance, entrance platform and doors, horizontal and vertical transportation, rooms (general reception room and the VIP room), public room (conference rooms, lecture hall, the hall of justice etc.), public toilet, service desk, public telephone, drinking water and other relevant facilities.

7. the scope of the barrier free design for commercial and service buildings should be in accordance with the following provisions

Business and service construction, must be in the following parts: the design of barrier free facilities building entrance portal and ordinary business district, business district, from the horizontal and vertical transportation, dining halls, recreation room, customer rest rooms and services, public toilet, hotels, restaurants, guest houses, guest room and public part of part of the total service desk business, Taiwan, ATM, query table, clearing channel, public telephones, drinking fountains, parking and other relevant facilities. It includes department stores, shopping malls, supermarkets, vegetable markets, restaurants, restaurants, food stores, finance, posts and telecommunications, guest houses, training centers, hotels, restaurants, hotels, bathing, beauty salons, funeral parlour buildings, etc.

乐发II5008. the scope of the barrier free design for the culture and commemorative buildings should be in accordance with the following provisions

Cultural and memorial buildings, must be in the following parts: the design of barrier free facilities construction base (pedestrian access, parking spaces), building entrance, entrance platform and doors, horizontal and vertical transportation, reception room, lounge, and information query service, cashier, directory hall, reading room, reading room, exhibition hall, lecture hall and the display room, audio-visual room, public toilet, ticket office, desk, public telephones, drinking fountains and other relevant facilities. It includes cultural museum, library, science and Technology Museum, museum, exhibition hall, archives, memorial hall, memorial tower, monument, Monument and so on.


This article URL:http://bypiju.com/en/news/372.html

Related tags:Chongqingbarrierfreehandwholesale

Recently Viewed:

s
e
r
v
i
c
e
二维码

Scan QR code

Welcome to leave a message
Please enter a message here.
name
Contact
Phone
Phone
Email
Email
Address
ASddress